Imaging System
MRK200 Modular Infrared /
Fluorescence
Build complete imaging
systems for virtually any application with Siskiyou MRK modules. The IPS200 motorized XY platform supports and the MRK100 imaging tower are the backbone for custom microscope systems. The IPS200 is a fully motorized XY stage with 50mm of travel at 0.2μm resolution with a handheld controller. The center chamber platform
is easily set at various heights for various sample thicknesses. The center chamber is an industry standard 10.8cm diameter that accepts a wide variety of components. The modular MRK200 system uses our 200cr series stages for 50mm of X and Y travel. The large travel range maximizes access to the chamber and manipulators, while facilitating mounting of stereotaxic holders for in vivo experiments.
The MRK100 is a camera tower with IS-GCI condenser lens, LED light source (IR or warm white – others available on request) and upper optics
tube. The upper optics tube is mounted to a Z-axis focus drive with 50mm of motorized travel. This stage can be connected to our DR1000 digital read-out to facilitate
returning to the focal plane.
The objective mount is a two position “flipper” for high and low magnification
objectives. Above the objective flipper is a CBH-1 beamsplitter
module containing a dichroic beamsplitter tube assembly. Inside of the assembly is a single position dichroic/ emission-filter mount. This mount can be slid into position for fluorescence experiments and out of the light path for gradient contrast imaging experiments. On the opposite
side (right) of the CBH-1 assembly is a port for introducing virtually any light source – liquid crystal light guide from a fluorescence source, LED, fiber coupled or free-space laser. It has a port for the excitation filter. CBH-1 modules can be stacked to accommodate more than one light source or detector. Above the CBH-1 module(s) is a tube lens and C-mount to accommodate your camera. You can configure a complete system that’s easy to modify as your experiment evolves – with Siskiyou MRK modules
|
|
| |
| |
| |
|
Nucleus
Accumbens
Medium spiny neurons 250 micron slices imaged
with Hamamatsu CCD camera and controller
through an Olympus 40X UM Plan Fluorite water
lens with 0.80 NA.
Images supplied by Zach Jeanes, R.A. Morrisett
Laboratory,
College of Pharmacy, University of Texas at
Austin.
  |
 |

Fluorescence image of cultured
neuroblastoma
cells (SH5Y cells)
|
Abstract by;
Steven J. Tavalin, Ph.D
Associate Professor
Department of Pharmacology
University of Tennessee Health Science Center
Abstract
|
|
| |
|
|
|

click on button for order form
Prices listed are for domestic U.S sales. International sales could be 10% higher
|
|
|
|